Integration Rod End In Line 3kg 4kg Panel Mount Load Cells Hand Scales miniature sensors
Product Details:
Place of Origin: | DONGGUAN,GUANGDONG,CHINA |
Brand Name: | UCHI |
Certification: | SGS.ISO. |
Model Number: | CZL928HC |
Payment & Shipping Terms:
Minimum Order Quantity: | 500pcs |
---|---|
Price: | Negotiable |
Packaging Details: | Bulk |
Delivery Time: | 14 workdays |
Payment Terms: | T/T, Western Union, MoneyGram |
Supply Ability: | 500000pcs |
Detail Information |
|||
Product Name: | Panel Mount Load Cells | Material: | Aluminium Alloy |
---|---|---|---|
Surface: | Anodized Treatment | Application: | Hand Scales |
PN: | CZL928HC | HS Code: | 9031809090 |
High Light: | load cell miniature,small load cell |
Product Description
Integration Rod End In Line 3kg 4kg Panel Mount Load Cells Hand Scales miniature sensors
Quick details
Introduction
A load cell is a force sensing module - a carefully designed metal structure, with small elements called strain gauges mounted in precise locations on the structure. Load cells are designed to measure a specific force, and ignore other forces being applied. The electrical signal output by the load cell is very small and requires specialized amplification. Fortunately, the 1046 PhidgetBridge will perform all the amplification and measurement of the electrical output.
Load cells are designed to measure force in one direction. They will often measure force in other directions, but the sensor sensitivity will be different, since parts of the load cell operating under compression are now in tension, and vice versa.
This Single Point Load Cell is used in small jewelry scales and kitchen scales. It’s mounted by bolting down the end of the load cell where the wires are attached, and applying force on the other end in the direction of the arrow. Where the force is applied is not critical, as this load cell measures a shearing effect on the beam, not the bending of the beam. If you mount a small platform on the load cell, as would be done in a small scale, this load cell provides accurate readings regardless of the position of the load on the platform.
Product specifications
1. Rated Load | 3kg , 4kg |
2. Rated Output | 1.0±0.1 mV/V |
3. Zero Balance | ±0.5 mV/V |
4. Input Resistance | 500±10Ω |
5. Output Resistance | 500±10Ω |
6. Excitation Voltage | 5-10VDC |
7. Nonlinearity | 0.3%F.S |
8. Hysteresis | 0.3%F.S |
9. Repeatability | 0.3%F.S |
10.Creep(30min) | 0.1%F.S |
11.Operating Temperature | -10℃ To +40℃ |
12.Temperature Effect on Zero | ±0.05%F.S/10℃ |
13.Temperature Effect on Span | ±0.05%F.S/10℃ |
14.Insulation Resistance | 2000MΩ(50VDC) |
15. Safe Overload | 150%F.S |
NumberType="1" TCSC="0" w:st="on">5mm 4-wire shielding cable)