• Positive Temperature Coefficient Thermistor For Telecom Over-current Protection
Positive Temperature Coefficient Thermistor For Telecom Over-current Protection

Positive Temperature Coefficient Thermistor For Telecom Over-current Protection

Product Details:

Place of Origin: Dongguan,Guangdong,China
Brand Name: UCHI
Certification: UL,SGS,ROHS
Model Number: PTC Thermistor for Telecom Over-current Protection

Payment & Shipping Terms:

Minimum Order Quantity: 5000PCS
Price: Negotiable
Packaging Details: Bulk
Delivery Time: 7 working days
Payment Terms: T/T,Paypal,Western Union,Money gram
Supply Ability: 600,000,000PCS Per Month
Get Best Price Contact Now

Detail Information

Highlight:

high temperature thermistor

,

positive temperature coefficient thermistor

Product Description

Positive Temperature Coefficient Thermistor For Telecom Over-current Protection

 

Quick Details

 

Compliant with ITU-T K20 K21 K45 

--Basic level lightning surges (10/700μs)
--Basic level power Induction (600V,1A,0.2S)
--Power contact criteria A/B (230V,15min.)
Suitable for continuous connection to main voltage 110/230 VAC in tripped (high ohmic) condition.
Round leadless disk thermistor availble for combined usage of PTC and primary protection, e.g gas arrestor.
Typical Resistance @25C (R25) 10 ohm, 12 ohm, 18 ohm, 20 ohm, 25 ohm, 50 ohm, 55 ohm.
Matching available with narrow resistance tolerance.
Tight resistance tolerance maintained after switching.
Negligible resistance drift after soldering or switching.

 

 

Description

 

This series of ceramic PTC (positive temperature coefficient ) thermistors help provide protection against power cross, power induction surges and lighting surge defined in ITU, Telcordia, UL. Available in chip, radial-leaded coated and non-coated, SMD, twin vertical surface mount configuration. PTC thermistor overcurrent protector provides reversible, self-resetting protection against over-currents of telecommunication line protector units, improve the reliability of custom premises and network equipment.
Ceramic PTC thermistors can be found providing re-settable line protection at the exchange, monitoring hot spots and protecting ringers, battery feeds, transformers and relay circuits. Also used extensively to protect the mobile phone's battery pack against overcharging in land-based and radio mobile communications.

Advanced developments in telecom equipment in recent years have radically altered the protection requirements of both exchange and subscriber equipment. The PTC thermistor must protect the telephone line circuit against overcurrent, which may be caused by the following examples:
Surges due to lighting strikes on or near to the line plant.
Short-term induction of alternating voltage from adjactent power lines or railway systems, usually caused when these lines or systems develop faults
Direct contact between telephone lines and power lines.
To provide good protection under such conditions, a PTC thermistor is connected in series with each line, usually as secondary protection; However, even with primary line protection (usually a gas discharge tube), the PTC thermistor must fulfill severe requirements.
Surge pulses of upto 2KV can occur and in order to withstand short term power induction, the PTC thermistor must withstand high voltages. If the line has primary protection, a 220V to 300V PTC thermistor is adequate. Without primary protection, 600V PTC device is necessary. We can manufacture a series of PTC thermistor fulfilling both requirements.

 
 

Application

 
It's applicable to various types of fluorescent lamp, electronic ballast and electronic energy-saving lamp. The PTC can be connected across the lamp resonator without changing the circuits. It can change hard start of the ballast and electronic energy-saving lamp to preheated start and the preheating time of the filament can come up to 0.4-2 seconds, which will extend the service life of the fluorescent tube by over 4 times.
 
 

Specification

 

Typical Application of PTC Thermistor in Telecommunication Protection

Central Office Switching Equipment (C.O): analog and digital line cards, POTS, T1/E1 equipment, xDSL modems and splitters, multiplexers, CSU/DSU, servers.
Primary Protection Modules: MDF (main distribution frame) modules, network interface devices (NIC).
Custom Premises Equipment, also known as subscriber terminal equipment (T.E.), IT equipment: Modem, phone sets, fax machines, phone wall outlet (plugs), alarm systems, answering machine, PBX systems, ADSL Splitters, internet appliance, POS terminals.
Access Network hardware, LAN WAN equipment, Powered Ethernet systems, VoIP (voice over IP equipment), integrated voice data (IVD), Set-top box (S.B), etc.

 

Telecom PTC Thermistor Features

 

Compliant with ITU-T K20 K21 K45 

--Basic level lightning surges (10/700μs)
--Basic level power Induction (600V,1A,0.2S)
--Power contact criteria A/B (230V,15min.)

Suitable for continuous connection to main voltage 110/230 VAC in tripped (high ohmic) condition.
Round leadless disk thermistor availble for combined usage of PTC and primary protection, e.g gas arrestor.
Typical Resistance @25C (R25) 10 ohm, 12 ohm, 18 ohm, 20 ohm, 25 ohm, 50 ohm, 55 ohm.
Matching available with narrow resistance tolerance.
Tight resistance tolerance maintained after switching.
Negligible resistance drift after soldering or switching.

 

PTC Thermistors Electrical Performances

Rated zero-power Resistance(R25)
Operating temperature range: 25±2℃, Within the allowable tolerance.

Non-operating characteristic
Operating temperature range: 40±2℃. In static air for 30min.Max. voltage: 60VDC. Non-operating current. Energized time: 60min. (R-R25)/R25≤50%

Over-current operating characteristic
Operating temperature range: 25±2℃,Max. voltage of power supply: 220Vrms.Test the time for the current decrease to limited value. See the spec. Table.

Over voltage withstanding (Power line contact)
Voltage of power supply: 250VAC, Initial current: 3A,Energized time: 30min . Restore time in room temperature is 4 hours, then test the R25. ΔR/R25≤20%.

Over current withstanding
Max. voltage of supply: 220VAC, Initial current: 3A. ON 60S, OFF 600S,Cycle:30 times, Restore time in room temperature is 4 hours, then re-test the Rn. 
ΔR/Rn≤20%.

Surge current withstanding
Current waves: 10/1000μS, Minimum opening circuit voltage: 1.0kv, Peak current: 25A, Interval: 3min, Cycle:30 times, Restore time in room temperature is 4 hours, then re-test the R25. ΔR/R25≤20%.

Induction voltage current withstanding (Only for maximum voltage more than 600V) 
Max. voltage of supply: 650VAC, Initial current: 1.1A.,ON 60S, OFF 600S,Cycle:10 times, Restore time in room temperature is 4 hours, then re-test the R25. ΔR/R25≤20%.

Fail Model
I. Voltage of power supply: 250VAC. Initial current: 10Arms,
II. Voltage of power supply: 600VAC. Initial current: 15Arms.
III. Voltage of power supply: 650VAC. Initial current: 10Arms.
Energized time: 30min. High resistance or open circuit is allowable. Low resistance state or firing is not allowed..

Restore time
The necessary time of a PTC to return to twice of R25. ≤60S.

Telecom PTC Thermistor Outline and Dimensions (unit:mm)

Fig.1

Fig.2

Fig.3

Fig.4

Telecom PTC Thermistors round chips drawingTelecom PTC Thermistors round chips thickness

Telecom PTC Thermistors rectangluar chips drawingTelecom PTC Thermistors rectangluar chips thickness Telecom PTC Thermistors radial leaded resin coated formTelecom PTC Thermistors radial leaded resin coated form Telecom PTC Thermistor radial leaded non-coating construction
Fig.5
Telecom PTC Thermistor SMD Construction

PTC Thermistor for Telecom Line Card Protection Application

Part number

Resistance @25C 
R25

(Ohm)

Non-trip current 
Int(mA)

Trip current
@25C

It

(mA)

Tripping time at max current

(Sec)

Max. current
Imax

(A)

Max. voltage
Vmax

(V)

Fail model Dimension (mm)
@25C @40C Dmax Tmax Φd
MZ23-10RM130 10 ohm 130mA 100mA 260mA <0.2s 1.0A 250V 250V/10A 7.5 4.0 0.6
MZ23-10RM150 10 ohm 150mA 100mA 260mA <0.3s 2.0A 250V 250V/10A 9.0 5.0 0.6
MZ23-12RM130 12 ohm 130mA 100mA 260mA <0.3s 2.0A 250V 250V/10A 9.0 5.0 0.6
MZ23-12RM090 12 ohm 90mA 60mA 160mA <0.2s 2.0A 250V 250V/10A 9.0 5.0 0.6
MZ23-20RM100 20 ohm 100mA 80mA 200mA <0.2s 3.0A 250V 250V/10A 9.0 4.0 0.6
MZ23-35RM090 35 ohm 90mA 75mA 180mA <0.2s 3.0A 250V 250V/5A 9.0 5.0 0.6
MZ23-40RM080 40 ohm 80mA 70mA 160mA <0.2s 3.0A 250V 250V/5A 9.0 5.0 0.6
MZ23-50RM070 50 ohm 70mA 60mA 150mA <0.2s 3.0A 250V 250V/5A 9.0 5.0 0.6
MZ23-50RM075 50 ohm 75mA 60mA 150mA <0.2s 3.0A 650V 650V/10A 9.5 5.0 0.6
MZ23-55RM070 55 ohm 70mA 60mA 150mA <0.2s 3.0A 650V 650V/10A 9.5 5.0 0.6
MZ25-9R0M160 9 ohm 160mA 130mA 330mA <0.8s 3.0A 250V 250V/10A 10.5 4.5 0.6
MZ25-25RM100 25 ohm 100mA 80mA 220mA <0.2s 3.0A 250V 250V/10A 6.6 4.0 0.6
MZ25-25RM120 25 ohm 120mA 100mA 300mA <0.4s 3.0A 250V 250V/10A 8.2 4.0 0.6
MZ26-10RM180SMD 10 ohm 180mA 140mA 360mA <5.0s 1.0A 250V 250V/10A / / /
MZ26-25RM130SMD 25 ohm 130mA 100mA 270mA <0.3s 3.0A 250V 250V/10A / / /
MZ26-50RM090SMD 50 ohm 90mA 70mA 190mA <0.2s 3.0A 250V 250V/5A / / /
MZ26-20RM100SMD 20 ohm 100mA 80mA 200mA <0.2s 3.0A 250V 250V/10A / / /

 

Note: Standard Resistance @25C (R25) allowable tolerance +/-20%, if not specified.

 

PTC Thermistor for Telecom MDF (Main Distribution Frame) Protection Application
Part number

Resistance @25C 
R25

(Ohm)

Non-trip current 
Int

(mA)

Trip current @25C 
It

(mA)

Tripping time at max current

(Sec)

Max. current 
Imax

(A)

Max. voltage 
Vmax

(V)

Dimension (mm)
@25C @40C Dmax Tmax Φd
MZ21-18RM110 18 ohm 110mA 90mA 220mA <0.15s 3A 250V 5.5 1.5 /
MZ21-18RM125 18 ohm 125mA 110mA 250mA <0.18s 3A 250V 5.5 2.0 /
MZ21-18RM130 18 ohm 130mA 110mA 260mA <0.18s 3A 250V 6.2 2.0 /
MZ21-20RM085 20 ohm 85mA 70mA 170mA <0.18s 3A 250V 6.2 2.0 /
MZ21-18RM135 18 ohm 135mA 110mA 270mA <0.2s 3A 250V 6.6 2.0 /
MZ21-10RM150 10 ohm 150mA 130mA 350mA <4.0s 3A 230V 7.2 1.5 /
MZ25-25RM055 25 ohm 55mA 45mA 110mA <0.4s 1A 230V 5.3 4.0 0.6
MZ25-25RM060 25 ohm 60mA 50mA 120mA <0.4s 1A 230V 5.3 4.0 0.6
MZ25-20RM145 20 ohm 145mA 100mA 250mA <0.2s 3A 250V 6.6 4.0 0.6
MZ25-10RM130 10 ohm 130mA 110mA 260mA <4.0s 1A 230V 6.6 4.0 0.6
MZ25-10RM150 10 ohm 150mA 135mA 300mA <7.0s 1A 230V 8.2 4.0 0.6
MZ25-18RM125 18 ohm 125mA 110mA 250mA <1.0s 1A 230V 5.5 4.0 0.6
MZ23-18RM135 18 ohm 135mA 110mA 270mA <0.2s 3A 250V 7.5 4.5 0.6
MZ23-18RM110 18 ohm 110mA 90mA 220mA <0.2s 3A 250V 9.0 4.5 0.6
MZ23-20RM100 20 ohm 100mA 80mA 200mA <0.2s 3A 250V 9.0 4.5 0.6
MZ23-25RM085 25 ohm 85mA 75mA 170mA <0.7s 1A 230V 6.5 5.0 0.6
MZ23-25RM090 25 ohm 90mA 70mA 180mA <0.2s 3A 250V 9.0 4.5 0.6

 

 

Note: Standard Resistance @25C (R25) allowable tolerance +/-20%, if not specified.

 

Positive Temperature Coefficient Thermistor For Telecom Over-current Protection 8Typical telephone line showing where PTC thermistors can be used for overcurrent protection

Typical telephone line showing where PTC thermistors can be used for overcurrent protection

PTC Thermistors telecom protection circuit

An example of PTC Thermistors for telecom circuit protection

 

Competitive Advantage:

 

  1. Factory supply directly

  2. Completed certificates such as UL,VDE,SGS,etc and high quality available

  3.  Quick delivery

  4. Best after-sales services

  5. OEM & ODM available

 

Positive Temperature Coefficient Thermistor For Telecom Over-current Protection 11

 

 

Want to Know more details about this product
I am interested in Positive Temperature Coefficient Thermistor For Telecom Over-current Protection could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.