• Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA
Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA

Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA

Product Details:

Place of Origin: Dongguan China
Brand Name: Uchi
Certification: CE / SGS / ISO9001
Model Number: OBV-I25-2

Payment & Shipping Terms:

Minimum Order Quantity: 200 piece
Price: Negotiate
Packaging Details: export package / Negotiate
Delivery Time: 5-15 days after payment
Payment Terms: T/T, L/C, Western Union
Supply Ability: 60000 pieces per month
Get Best Price Contact Now

Detail Information

Uc: 275V Condition: 100% Original
CertificationCE,CQC: CE / CQC / SGS System Voltage: 220V
Environment Temperature: (-25℃~+60℃) Status Indicator: Green(good)/red(need Replacement)
Response Time (L-N): ≤100ns Protection Rating: IP 20
Iimp(10/350μs): 25ka In(8/20μs): 100kA
Type: I
High Light:

Type I Surge Protection Device SPD

,

Iimp 25kA Surge Protection Device SPD

,

Multilayer Graphite Ignition Structure SPD Device

Product Description

Multilayer Graphite Ignition Structure Type I SPD Surge Protection Device Iimp 25kA

Uc(maximum continuous operating voltage) 275V
Iimp(impulse discharge current for class I test) 25kA
In(nominal discharge current for class II test) 100kA
Up(voltage protection level) ≤2.0kv
response time ≤100ns
Housing Material thermoplastic material
Housing self-extinguishing class UL94_V0
Temperature range -40℃+80℃
Humidity range 5%RH~95%RH
Elevational ≤3000m
Method of connecting wire multiple
(Connect In Parallel )
Mounting method DIN:35mm
IP(degree of protection of enclosure) IP20
Application standard GB18802-1;IEC61643-1

 

 

 

Product features:

1. Multilayer graphite ignition structure
2. Integrated surge protector unit
3. Withstand up to 50kA (10/350 μs) of lightning strike
4. Action response time is less than 100ns

 

 

Surge protection device T1,T2,T3 relative info

1. According to the definition of IEC61643.1 standard: base on the application environment and test requirements, it can be divided into class I test, class II test and class III test, which are identified as "T1", "T2" and "T3". The test waveforms weremaximum impulse current Iimp (10/350μs); In (8/20μs), impulse voltage of 1.2/50μs. The energy difference between T1 and T2 is huge, T1 being hit directly and T2 being affected by the shock wave

2. From the point of view of the product analysis, as to T1, T2 and T3 level lightning protection device can not be used "advantage" and "disadvantage" to distinguish good or bad, because these lightning protection device each with different use. These can be compared according to the environment and energy used. T1 is applied environment LPZ0A or LPZ0B and LPZ1 interface area, used for lightning high incidence area, lightning current intensity is large level I protection. According to the building lightning protection code, Class I buildings should have T1 SPD of no less than 12.5kA (10/350μs), and local laws and regulations will have more stringent requirements, T1 SPD impulse current will be larger, and T2 SPD should not be less than 60kA (8/20μs). The SPD installation of II and III buildings is different.

3. Class T2 and Class T3 should be installed base on the way of gradual weakening of lightning protection energy and the required configuration of insulation and voltage resistance of protection equipment. For example, the T2 class and T3 class SPD can achieve low residual pressure and more effective protection for equipment. These lightning protection devices have different uses, can be configured according to the appropriate situation of lightning protection device

 

 

 

 

 

 

 

 

 

 

Want to Know more details about this product
I am interested in Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.