• CQC Approved Antenna Lightning Arrestor , PLC Surge Protection 10kA
CQC Approved Antenna Lightning Arrestor , PLC Surge Protection 10kA

CQC Approved Antenna Lightning Arrestor , PLC Surge Protection 10kA

Product Details:

Place of Origin: Dongguan China
Brand Name: Uchi
Certification: CE / SGS / ISO9001
Model Number: OBVW-N/50C

Payment & Shipping Terms:

Minimum Order Quantity: 200 piece
Price: Negotiate
Packaging Details: export package / Negotiate
Delivery Time: 5-15 days after payment
Payment Terms: T/T, L/C, Western Union
Supply Ability: 60000 pieces per month
Get Best Price Contact Now

Detail Information

Name: Antenna-fed Lightning Arresters Condition: 100% Original
CertificationCE,CQC: CE / CQC / SGS Usage: Lightning Protection
Material: Brass Interface: N
Insertion Loss (user): Less Than 0.1db Impedance: 75Ohm
Nominal Discharge Current In: 10kA Horse Power: <300W
High Light:

antenna lightning arrestor

,

CQC PLC surge protection

,

10kA plc surge protection

Product Description

Surge Protection Device , Antenna-Fed Lightning Arresters For PLC Applications

 

Scope of application:
Antenna-fed lightning arresters are suitable for lightning protection of various radio frequency signal receiving and sending systems. Connected in series in the antenna to prevent surges from intruding into the equipment along the feeder and causing damage.
The selection of the antenna feeder lightning protection device needs to select the matching frequency range and interface parameters. Welcome to inquire Anxun Lightning Protection Company.

 

Technical and Parameters

  OBVW-
BNC/75C
OBVW-
BNC/50C
OBVW-
N/75C
OBVW-
N/50C
OBVW-
F/75C
OBVW-
F/50C
Maximum Continuous Operating Voltage Uc (~) DC68V / AC130V / AC280V
Nominal Discharge Current In (8/20µs)kA 10kA
Maximum discharge current Imax (8/20µs)kA 20kA
Maximum peak power (W) <300
Interface BNC N F
Voltage protection level (Up) <600V
Bandwidth (MHz) 0-3000
Standing wave ratio, VSWR ≤1.2
Insertion Loss ≤0.1db
Impedance(Ω) 75Ω 50Ω 75Ω 50Ω 75Ω 50Ω

CQC Approved Antenna Lightning Arrestor , PLC Surge Protection 10kA 0
Advantage:

• Lower Prices
• Low Capacitance
• High Discharge Current
• Continuous and repeated protection in intense environment
 
Application
AC/DC distribution
Power supplies
Industrial automation
Telecommunications
Motor controls systems
PLC applications
Power transfer equipment
HVAC applications
AC drives
UPS systems
Security systems
IT/Data centers
Medical equipment
 
Transient voltage surgesin lv power lines
Transient overvoltages are voltage surges that can reach tens ofkilovolts with a duration of the order of microseconds.Despite theirshort duration, the high energy content can cause serious problemsto equipment connected to the line, from premature aging to
destruction, causing disruptions to service and financial loss.Thistype of surge can have various different causes, including
atmospheric lightning directly striking the external protection(lightning rods) on a building or transmission line or the associatedinduction of electromagnetic fields on metallic conductors.
Outdoor and longer lines are the most exposed to these fields,which often receive high levels of induction.
It is also common for non-weather phenomena, such as
transformer centre switching or the disconnection of motors orother inductive loads to cause voltage spikes in adjacent lines.
 
Surges in telecom andsignalling networks
Surges tend to induce currents in allmetal conductors; not only are thepower lines affected, but so are allcables to a greater or lesser extent,depending on the distance to the focusof the surge.
Although a lower current is induced,the effect produced is equally or moredestructive, due to the greatersensitivity of electronic equipmentconnected to communications lines(telephone, Ethernet, R, etc.).
 
Importance of theground connection
Overvoltage protectors (SPD) divert excess energy toground, so limiting the peak voltage to an acceptablevalue for connected electrical equipment.
A ground connection in adequate condition is, therefore,a key aspect for effective protection against overvoltages.Monitoring ground connection condition guaranteesproper operation of surge protection devices.
 
Comprehensive protection
An effective overvoltage protection must combine thefollowing protection systems:
External protection (ESE lightning rods and faradization).System for protection against direct lightningstrike.These capture the lightning within the protectedarea and lead it, in a controlled manner, safely to ground. Internal protection (power frequency overvoltage andsurge protection devices). Equipment designed to protectagainst the effects of overvoltages in equipment connected to the power supply systems and/orcommunications networks.Grounding systems (grounding and insulation monitoring).Systems that allow atmospheric dischargecurrents to be dispersed into the ground. The need formonitoring the grounding system.CUAJE offers a widerange of products for each of these systems. It alsodevelops custom products, provides advice and consultingservices and the best possible aftersales service.
 
FAQ

 

Q: Can I get some samples?

A: Yes, Sample orders welcomed.

 

Q: Can I use my own Logo or design on goods?

A: Yes, Customized logo and design on mass production are available.

 

Q:What is the delivery time?

A: 3 days for samples, 7-15 days for mass production.

 

Q: What is the payment term?

A: T/T, L/C at sight, West union , Paypal, etc

 

 

 

Want to Know more details about this product
I am interested in CQC Approved Antenna Lightning Arrestor , PLC Surge Protection 10kA could you send me more details such as type, size, quantity, material, etc.
Thanks!
Waiting for your reply.