In 60KA Surge Protection Device SPD , CQC 2 Pole Surge Protector

In 60KA Surge Protection Device SPD , CQC 2 Pole Surge Protector

Product Details:

Place of Origin: Dongguan China
Brand Name: Uchi
Certification: CE / SGS / ISO9001
Model Number: OBV10-I-15

Payment & Shipping Terms:

Minimum Order Quantity: 200 piece
Price: Negotiate
Packaging Details: export package / Negotiate
Delivery Time: 5-15 days after payment
Payment Terms: T/T, L/C, Western Union
Supply Ability: 60000 pieces per month
Get Best Price Contact Now

Detail Information

Name: Power Surge Protector Poles Number: 1P,2P,3P,4P,(+NPE)
Uc: 255/275/320/385VAC Limp: 15KA
In: 60KA Imax: 100KA
Up: 2,5kv Protection: IP20
Color: White Connections: TT/TN
Protection Modes: L/N CertificationCE,CQC: CE / CQC / SGS
High Light:

60KA Surge Protection Device SPD

,

CQC 2 Pole Surge Protector

,

Surge Protection Device SPD CQC

Product Description

High Current Power Surge Protection Device , Protection IP20


OBV10-I-15

 

Surge protectors OBV10-I-15 meet the type 1 requirement class according to IEC 61643-11. These devices protect low-voltage consumer systems from overvoltages of all types and are available in single-pole to four-pole versions.The voltage-limiting,high-performance spark gaps provide several benefits.A short response time, a low protection level and high current leakage capability with long service life.


Technical Parameters

 

Model: OBV10-I-15-Pluggable
Maximum continuous operating voltage Uc V 255/275/320/385
SPD to EN 61643-11     Type 1
SPD to IEC 61643-1     class I
LPZ     0→2
Lightning impulse current (10/350μs) Iimp kA 15
Lightning impulse current (10/350μs) [total]   kA 60
Nominal discharge surge current (8/20μs) In kA 60
Maximum discharge surge current (8/20μs) Imax kA 100
Voltage protection level Up kV 2,5
Response time tA ns <25
Follow current quenching capacity Ipeak Ifi peak kA 12.5
Maximum back-up fuse   A 315
Temperature range ϑ °C -40℃~+85℃
Protection rating     IP 20
Connection cross-section, rigid   mm² 10-50
Connection cross-section, multi-wire   mm² 10-35
Connection cross-section, flexible   mm² 10-25
 

Feature
 

Indoor fixed installation, voltage limited type.
It adopts 35mm standard rail.
The response time in the 25 nanosecond.
When the SPD works normally, the visible window displays green, and when it fails, it displays red.

 
Application

 

●AC/DC distribution
●Power supplies
●Industrial automation
●Telecommunications
●Motor controls systems
●PLC applications
●Power transfer equipment
●HVAC applications
● AC drives
●UPS systems
●Security systems
●IT/Data centers

 
Note: The system lightning protection does not guarantee that the equipment will not be 100% damaged by lightning; the power system must be multi-level lightning protection;
The complete lightning protection system includes external lightning protection and internal lightning protection. External lightning protection refers to: lightning receptors, down conductors, and grounding bodies, which are mainly used to defend against direct lightning strikes. Internal lightning protection includes: shielding, reasonable wiring, safe distance, equipotential connection, overvoltage protection, etc., mainly used to prevent lightning induction, ground potential counterattack, lightning wave intrusion, etc.
 

Others


Technology SPD parameter(Note:According to user requirement ,can be customized Uc=140V,440V,550V,voltage range of range of the SPD):

Type No. Rated Voltage(V) Un Continuous Voltage Uc(V~) Standard Discharge Current In(KA)

Max Discharge Current
Imax(KA)

Protection Level(KA~) Response Time(ns)
DGM1(2)-D5 220/380

275/320
385/420

5 10 1.2 ≤25
DGM1(2)-D10 10 2 1.6
DGM1(2)-C20 20 40 1.8
DGM13-B30 30 60 .2.2
DGM3(4)-B40 10 80 2.4
DGM(4)-B60 60 100 2.8
DGM-N-PE 220/255 40/60 60/80 1.2 ≤100

 

Tip1: Lightning protection is probabilistic protection, and we cannot provide 100% protection.


First, lightning discharge itself has a certain degree of randomness, and lightning parameters have certain statistical properties, which determines that all protective measures based on these statistical characteristics of lightning parameters cannot provide 100% protection. Such as: direct lightning protection-shielding characteristics; lightning current amplitude, waveform, etc. have statistical properties;
Second, the lightning protection equipment cannot prevent the formation of lightning flashes;
Third, lightning protection devices cannot ideally eliminate all interference voltages/currents. The fundamental purpose of taking protective measures is to ensure that most of the energy caused by interference does not spread to the vulnerable parts of the device and the staff.
Finally, the cost of protection against high-level surges with a small probability of occurrence has risen sharply.


Tip2:How can we distinguish the quality of the lightning arrester?

1. It can be seen from the reaction time: determine whether the lightning arrester can respond in time and quickly discharge the lightning current.

2. It can be seen from the insertion loss: this refers to the installation of a lightning protector, the impact of this lightning protector on the line, the smaller the better

3. It can be seen from the number of impact resistance: determines the service life of the lightning arrester. Generally, the gas discharge tube will not drop after being placed for a period of time. If you want to check its quality, you can use an adjustable high-voltage DC power supply to test .

 

What skills should lightning protectors have in the selection?
 
1.Confirm power supply system
First of all, you must determine what your power distribution system is like, whether it is TT, TN or IT system. After determining the power distribution system, you can choose the protection mode and wiring method of the lightning arrester to select the appropriate lightning arrester.
For example, TN-C uses 3P lightning protection device, TN-S uses 4P, TT uses 3P+N, etc.
 
2.Know the main parameters of the lightning arrester.
 
FAQ

 
Q: Can I get some samples?
A: Yes, Sample orders welcomed.
 
Q: Can I use my own Logo or design on goods?
A: Yes, Customized logo and design on mass production are available.
 
Q:What is the delivery time?
A: 3 days for samples, 7-15 days for mass production.
 
Q: What is the payment term?
A: T/T, L/C at sight, West union , Paypal, etc.

Want to Know more details about this product
I am interested in In 60KA Surge Protection Device SPD , CQC 2 Pole Surge Protector could you send me more details such as type, size, quantity, material, etc.
Thanks!